Pressure regulators (3/3): how to use a pressure regulator flow chart?

December 19, 2024 by
Pressure regulators (3/3): how to use a pressure regulator flow chart?
Laurent Dohogne, Awans

This article is brought to you by FITOK Valves & Fittings. To read the original article, click here


Principle and application of pressure regulators

The pressure regulators adopt a special flow path structure. When the high pressure medium flows through the orifice from the inlet, the flow rate of the medium increases and the pressure decreases, thus achieving the purpose of pressure regulation. In addition, the pressure regulators can balance the medium load generated by the inlet pressure and the outlet pressure by adjusting the spring load, so as to control the outlet pressure and maintain it, and the force balance of the pressure regulators meets the following formula:


Fload element = Fsensing element + Fcontrol element 


Where:

  • Fload element = range spring load
  • Fsensing element = outlet pressure × diaphragm effective area
  • Fcontrol element = inlet pressure × poppet effective area + poppet spring load


Structure Diagram of Pressure Regulators

The main purpose of the pressure regulators is to reduce the upstream inlet pressure to the set outlet pressure value and maintain it, so as to meet the specific system pressure requirements. Pressure regulators are widely used in the fields of special gas, high purity and the like.

Composition and function of a flow chart

The flow chart describes the relationship between flow rate (horizontal axis) and outlet pressure (vertical axis) of the pressure regulators at a given inlet pressure. From this chart, we can see the response state of the pressure regulators when the flow rate in the system changes. It describes the range of system pressures that a pressure regulator can maintain at given flow rates. 


Flow Chart of Pressure Regulators.



How to Use a Flow Chart?


Flow chart analysis

Valve manufacturers usually provide multiple flow curves for the same series of regulator at different inlet pressures and the same outlet pressure to illustrate the operating range of the regulator:

  • The horizontal axis represents the flow rate.
  • The vertical axis represents the outlet pressure value.
  • The inlet pressure is represented by curves of different colors, such as 3000 psig (206.8 bar), 2000 psig (137.9 bar) and 1000 psig (68.9 bar)

When the flow rate is 0, the outlet pressure shown in the vertical axis is the outlet set pressure.

The flow curve shows a "droop" trend, that is, under a certain inlet pressure and outlet set pressure conditions, with the flow rate gradually increases, the outlet pressure gradually decreases. As the internal structure and component limit, pressure regulators cannot provide a perfect horizontal flow curve in a particular regulating state. As a consequence, when the pressure regulators respond to the increase of flow rate, the outlet pressure will decrease to some extent.

For pressure regulator application, it is usually required to maintain a relatively constant outlet pressure when the system flow changes greatly. Therefore, the less droop of the flow curve, the better performance of the pressure regulator.

How to use a flow chart?

For a certain type of pressure regulator, first find the corresponding flow chart, and select the corresponding curve according to the actual inlet pressure and outlet set pressure values. Then find its corresponding point on the curve according to the horizontal axis flow rate scale and get the actual outlet pressure of that point from vertical axis. If the flow curve for the required pressure condition can't be found in the pressure regulator flow chart provided, a new curve can be deduced between two adjacent existing curves.

In addition, the flow chart provided by the manufacturer is based on test conditions when the test medium is nitrogen and the test temperature is 70℉ (20°C). If the actual system uses other medium and at other operating temperature, the flow rate scale in the horizontal axis of the flow chart needs to be modified according to formula (2), and the curve trend remains unchanged. 

Q2 = Q1 × FG × FT ​

Where

  • Q1 is initial flow rate scale,
  • Q2 is the modified flow rate scale,
  • FG is the gravity modified coefficient,
  • FT is the the temperature modified coefficient.

The values of FG and FT can be referred to in Table 1 and Table 2 respectively.


Table 1

.

Table 2


Selection example

For example, the flow chart for FITOK RDSC Series Sensitive Diaphragm Regulators is shown in the following figure. The customer requires to determine the outlet pressure when the inlet pressure is 3000 psig (206.8 bar), the outlet set pressure is 90 psig (6.2 bar), the operating temperature is 100°F (37°C), and the system medium (CO2) flow rate is 10 SCFM (283 SLPM).


Flow Chart of RDSC Series Pressure Regulators


Since the medium type and operating temperature required by the customer are inconsistent with the test medium and test temperature of the flow chart provided by the manufacturer, the flow rate scale shall be modified according to the gravity modified coefficient (FG) and temperature modified coefficient (FT).

As can be seen from Table 1, when the medium is carbon dioxide, the corresponding gravity modified coefficient FG is 0.80. And from Table 2, when the temperature is 100°F (37°C), the corresponding temperature modified coefficient FT is 0.97. Bring the initial flow rate scale (i.e. the horizontal axis value) in previous figure and FG and FT into formula (2), calculate to get the modified flow rate scale (example: 3.9 = 5 x 0.8 x 0.97).

Replace the horizontal axis in previous figure with the modified flow rate scale while keeping the vertical axis and flow curve the same to get a new flow chart as shown in following figure: 

Flow Chart of Pressure Regulators after Modification

As can be seen in this diagram, the flow curve for the customer's desired inlet pressure of 3000 psig (206.8 bar) and outlet set pressure of 90 psig (6.2 bar) is not shown. We can interpolate and analogize according to the two flow curves for an inlet pressure of 3000 psig (26.8 bar) and outlet set pressures of 75 psig (5.2 bar) and 100 psig (6.9 bar) to get a flow curve for the inlet pressure of 3000 psig (206.8 bar) and outlet set pressure of 90 psig (6.2 bar) as shown in the red curve in following Figure. 



Flow Chart after Interpolation and Analogy


From the flow curve (red curve) shown in this modified diagram, for the inlet pressure of 3000 psig (26.8 bar) and outlet set pressure of 90 psig (6.2 bar), find the point A on the curve with horizontal axis scale of 10 SCFM (283 SLPM), and get the actual outlet pressure of 84 psig (5.8 bar) from vertical axis.


Therefore, for RDSC Series Sensitive Diaphragm Regulators at the inlet pressure of 3000 psig (206.8 bar), the outlet set pressure of 90 psig (6.2 bar), the operating temperature of 100°F (37°C) and the system medium (CO2) flow rate of 10 SCFM (283 SLPM), the actual outlet pressure is 84 psig (5.8 bar).


Conclusion

By correctly using the flow chart of the pressure regulators, we can verify whether the working pressure range of the selected type of pressure regulators meets the customer's requirements, thus contributing to rapid and accurate part number selection. In addition, the flow chart can also reflect pressure regulators' pressure regulating performance. 

Do you need to select the right pressure regulator? Our experts are here to help:contact us! 